logo
Good price  online

products details

Home > Products >
ENT Probe
>
Tonsillectomy Plasma Wand ENT Probe for Plasma Surgery in Tonsillectomy Effective for Treating Repeated Acute Attacks of Chronic Tonsillitis

Tonsillectomy Plasma Wand ENT Probe for Plasma Surgery in Tonsillectomy Effective for Treating Repeated Acute Attacks of Chronic Tonsillitis

Brand Name: Better
Model Number: VF06E
MOQ: 1 Set
Price: 3200-8600USD
Packaging Details: Standard Carton
Payment Terms: L/C,T/T,MoneyGram
Detail Information
Place of Origin:
China
Certification:
iso, Cfda
Similar Brand:
Coblator II
Function:
Cutting, Ablation, Coagulation And Hemostasis
Technology:
Cold Radiofreqency Plasma
Application:
Arthroscopy, Joint Surgery, Meniscectomy, Cervical Disc Herniation, Lumbar Disc Herniation, RF Ablation Of Nucleus, Spinal Stenosis.
Properties:
Eyes,Nose And Throat Surgical Instruments,Ears,Abdominal Surgery Equipments
Type:
Needle,Hook,Other,Knife,Sinus Forceps
Material:
Stainless Steel,copper,Medical Grade German Stainless Steel
Product Name:
ENT Ear Instruments (gun Shape),surgical Lacrimal Probes,Nasal Probe,Laryngeal Mirror,ENT Surgical Probe For Ear
Feature:
Reusable,Minimally Invasive,less Pain,Low Working Tempature,no Bleeding
Supply Ability:
100000 sets per year
Highlight:
Rf Ablation System, Rf Ablation Devices
Product Description
Tonsillectomy Plasma Wand ENT Probe
This specialized ENT medical device is designed for plasma surgery in tonsillectomy procedures, effectively treating repeated acute attacks of chronic tonsillitis through minimally invasive technology.
Product Overview
The VF06E probe is specifically engineered for tonsillectomy, adenoidectomy, CAUP, UPPP, and nasal cavity lesion tissue treatment. Featuring a thinner diameter for pediatric use, the design incorporates separate liquid inflow and outflow channels to prevent cutter head blockage. The electrode surface is plated with special metal for extended durability, providing cutting, ablation, hemostasis, and coagulation functions when connected with the SPK-100 ENT plasma surgery system.
Clinical Applications
  • Repeated acute attacks of chronic tonsillitis
  • History of abscesses around the tonsils
  • Excessive tonsil hypertrophy affecting swallowing, breathing, or eustachian tube function
  • Simple III degree hypertrophy or near III degree hypertrophy tonsils
  • Patients with rheumatic fever, nephritis, arthritis, or rheumatic heart disease where tonsils are suspected as the lesion
  • Benign tonsil tumors
Key Functions
  • Bipolar or multipolar cutting with low temperature ablation, resection, hemostasis and coagulation
  • Minimally invasive, safe and reliable operation
  • Two ABLATION modes (including channeling, resection, hemostasis and ablation)
  • One PLACOAG mode (including hemostatic coagulation)
  • Multiple probe options with customized length, diameter, radian, and energy levels
  • Multi-function probe design enabling ablation, coagulation, hemostasis and resection without frequent probe changes
Tonsillectomy Plasma Wand ENT Probe medical device
Technical Specifications
Parameter Specification
Input Voltage 198-242V 50Hz (Export device converts automatically per customer requirements)
Output Power Ablation and resection: ≤360W
Coagulation and hemostasis: ≤110W
Working Frequency 110 KHz ± 10%
Dimensions 409 × 460 × 145mm (L × W × H)
Working Mode Ablation and resection: level 1-10
Coagulation: level 1-10
Weight 7kg
Cutting Principle
The technology relies on the mechanical kinetic energy of plasma in the electric field to lyse and ablate target tissue molecular bonds at 40-70°C. With thermal damage depth less than 0.5mm, the system minimizes trauma to adjacent normal tissues.
Product Advantages
Minimally invasive procedure, low temperature operation, and reduced hospital stay duration.
ENT Plasma Surgery System in clinical setting
Good price  online

Products Details

Home > Products >
ENT Probe
>
Tonsillectomy Plasma Wand ENT Probe for Plasma Surgery in Tonsillectomy Effective for Treating Repeated Acute Attacks of Chronic Tonsillitis

Tonsillectomy Plasma Wand ENT Probe for Plasma Surgery in Tonsillectomy Effective for Treating Repeated Acute Attacks of Chronic Tonsillitis

Brand Name: Better
Model Number: VF06E
MOQ: 1 Set
Price: 3200-8600USD
Packaging Details: Standard Carton
Payment Terms: L/C,T/T,MoneyGram
Detail Information
Place of Origin:
China
Brand Name:
Better
Certification:
iso, Cfda
Model Number:
VF06E
Similar Brand:
Coblator II
Function:
Cutting, Ablation, Coagulation And Hemostasis
Technology:
Cold Radiofreqency Plasma
Application:
Arthroscopy, Joint Surgery, Meniscectomy, Cervical Disc Herniation, Lumbar Disc Herniation, RF Ablation Of Nucleus, Spinal Stenosis.
Properties:
Eyes,Nose And Throat Surgical Instruments,Ears,Abdominal Surgery Equipments
Type:
Needle,Hook,Other,Knife,Sinus Forceps
Material:
Stainless Steel,copper,Medical Grade German Stainless Steel
Product Name:
ENT Ear Instruments (gun Shape),surgical Lacrimal Probes,Nasal Probe,Laryngeal Mirror,ENT Surgical Probe For Ear
Feature:
Reusable,Minimally Invasive,less Pain,Low Working Tempature,no Bleeding
Minimum Order Quantity:
1 Set
Price:
3200-8600USD
Packaging Details:
Standard Carton
Payment Terms:
L/C,T/T,MoneyGram
Supply Ability:
100000 sets per year
Highlight:
Rf Ablation System, Rf Ablation Devices
Product Description
Tonsillectomy Plasma Wand ENT Probe
This specialized ENT medical device is designed for plasma surgery in tonsillectomy procedures, effectively treating repeated acute attacks of chronic tonsillitis through minimally invasive technology.
Product Overview
The VF06E probe is specifically engineered for tonsillectomy, adenoidectomy, CAUP, UPPP, and nasal cavity lesion tissue treatment. Featuring a thinner diameter for pediatric use, the design incorporates separate liquid inflow and outflow channels to prevent cutter head blockage. The electrode surface is plated with special metal for extended durability, providing cutting, ablation, hemostasis, and coagulation functions when connected with the SPK-100 ENT plasma surgery system.
Clinical Applications
  • Repeated acute attacks of chronic tonsillitis
  • History of abscesses around the tonsils
  • Excessive tonsil hypertrophy affecting swallowing, breathing, or eustachian tube function
  • Simple III degree hypertrophy or near III degree hypertrophy tonsils
  • Patients with rheumatic fever, nephritis, arthritis, or rheumatic heart disease where tonsils are suspected as the lesion
  • Benign tonsil tumors
Key Functions
  • Bipolar or multipolar cutting with low temperature ablation, resection, hemostasis and coagulation
  • Minimally invasive, safe and reliable operation
  • Two ABLATION modes (including channeling, resection, hemostasis and ablation)
  • One PLACOAG mode (including hemostatic coagulation)
  • Multiple probe options with customized length, diameter, radian, and energy levels
  • Multi-function probe design enabling ablation, coagulation, hemostasis and resection without frequent probe changes
Tonsillectomy Plasma Wand ENT Probe medical device
Technical Specifications
Parameter Specification
Input Voltage 198-242V 50Hz (Export device converts automatically per customer requirements)
Output Power Ablation and resection: ≤360W
Coagulation and hemostasis: ≤110W
Working Frequency 110 KHz ± 10%
Dimensions 409 × 460 × 145mm (L × W × H)
Working Mode Ablation and resection: level 1-10
Coagulation: level 1-10
Weight 7kg
Cutting Principle
The technology relies on the mechanical kinetic energy of plasma in the electric field to lyse and ablate target tissue molecular bonds at 40-70°C. With thermal damage depth less than 0.5mm, the system minimizes trauma to adjacent normal tissues.
Product Advantages
Minimally invasive procedure, low temperature operation, and reduced hospital stay duration.
ENT Plasma Surgery System in clinical setting