logo
Good price  online

products details

Home > Products >
Plasma Surgery System
>
Adjustable Output Energy ENT Plasma Surgery System for Minimally Invasive Surgeries Low Temperature And Rapid Recovery

Adjustable Output Energy ENT Plasma Surgery System for Minimally Invasive Surgeries Low Temperature And Rapid Recovery

Brand Name: Better/Vanway
Model Number: SPK-100
MOQ: 1 piece
Price: Negotiable
Packaging Details: paper carton
Payment Terms: L/C,T/T,Western Union
Detail Information
Place of Origin:
CHINA
Certification:
ISO,CE
Product Name:
Adjustable Output Energy ENT Plasma Surgery System For Minimally Invasive Surgeries Low Temperature And Rapid Recovery
Operating Mode:
Ablation & Coagulation
Output Energy:
Adjustable
Application:
ENT Surgery
Advantage:
Minimally Invasive, Low Temperature
WorkingTemperature:
40-70 Degrees
Supply Ability:
1000000 set per year
Highlight:

Adjustable Output ENT Plasma Surgery System

,

Minimally Invasive Plasma Surgery System

,

Low Temperature ENT Surgery System

Product Description
Adjustable Output Energy  ENT Plasma Surgery System for Minimally Invasive Surgeries Low Temperature And Rapid Recovery
This ENT Plasma Surgery System is specifically designed for ENT procedures, featuring both ablation and coagulation modes that produce distinct tissue effects. The system enables minimally invasive treatments with low temperature operation and rapid patient recovery.
Clinical Applications
  • Turbinate reduction
  • Soft Palate and Uvula procedures
  • CAUP and UPPP surgeries
  • Tonsillectomy and Adenoidectomy
  • Laryngeal tumor removal
  • Papilloma and Vocal Polyps treatment
Technical Specifications
Input Volts 198-240V 50Hz / 100-120V 60Hz
Export device automatically converts per customer requirements
Output Power Ablation or resection: ≤351W
Coagulation or hemostasis: ≤111W
Working Frequency 100 KHz ± 10%
Dimension 405 × 440 × 130mm (L × W × H)
Working Mode Ablation and resection: level 1-10
Coagulation: level 1-10
Weight 7.0kg
Technical Principle
The plasma technology generates plasma energy by stimulating NaCl in physiological saline with a 100KHz square wave. High-speed charged particles in the plasma break molecular bonds of human tissue, causing proteins and other tissues to decompose and vaporize into low molecular weight gases including H₂, O₂, CO₂, N₂, and methane.
Under a stable 100KHz square wave electric field, particles achieve extended acceleration time, forming high-speed charged particles with kinetic energy sufficient to break molecular bonds while causing minimal damage to surrounding tissues. Cutting, ablation, and hemostasis procedures are completed within the 40-70℃ temperature range.
Plasma energy surgical system technical diagram
Technical System Diagram
Manufacturing Process
Factory manufacturing process step 1
Manufacturing Process Step 1
Factory manufacturing process step 2
Manufacturing Process Step 2
Exhibition Showcase
Medical exhibition display 1
Exhibition Display 1
Medical exhibition display 2
Exhibition Display 2
Medical exhibition display 3
Exhibition Display 3
Medical exhibition display 4
Exhibition Display 4
Medical exhibition display 5
Exhibition Display 5
Medical exhibition display 6
Exhibition Display 6
Good price  online

Products Details

Home > Products >
Plasma Surgery System
>
Adjustable Output Energy ENT Plasma Surgery System for Minimally Invasive Surgeries Low Temperature And Rapid Recovery

Adjustable Output Energy ENT Plasma Surgery System for Minimally Invasive Surgeries Low Temperature And Rapid Recovery

Brand Name: Better/Vanway
Model Number: SPK-100
MOQ: 1 piece
Price: Negotiable
Packaging Details: paper carton
Payment Terms: L/C,T/T,Western Union
Detail Information
Place of Origin:
CHINA
Brand Name:
Better/Vanway
Certification:
ISO,CE
Model Number:
SPK-100
Product Name:
Adjustable Output Energy ENT Plasma Surgery System For Minimally Invasive Surgeries Low Temperature And Rapid Recovery
Operating Mode:
Ablation & Coagulation
Output Energy:
Adjustable
Application:
ENT Surgery
Advantage:
Minimally Invasive, Low Temperature
WorkingTemperature:
40-70 Degrees
Minimum Order Quantity:
1 piece
Price:
Negotiable
Packaging Details:
paper carton
Delivery Time:
5-8 Work day
Payment Terms:
L/C,T/T,Western Union
Supply Ability:
1000000 set per year
Highlight:

Adjustable Output ENT Plasma Surgery System

,

Minimally Invasive Plasma Surgery System

,

Low Temperature ENT Surgery System

Product Description
Adjustable Output Energy  ENT Plasma Surgery System for Minimally Invasive Surgeries Low Temperature And Rapid Recovery
This ENT Plasma Surgery System is specifically designed for ENT procedures, featuring both ablation and coagulation modes that produce distinct tissue effects. The system enables minimally invasive treatments with low temperature operation and rapid patient recovery.
Clinical Applications
  • Turbinate reduction
  • Soft Palate and Uvula procedures
  • CAUP and UPPP surgeries
  • Tonsillectomy and Adenoidectomy
  • Laryngeal tumor removal
  • Papilloma and Vocal Polyps treatment
Technical Specifications
Input Volts 198-240V 50Hz / 100-120V 60Hz
Export device automatically converts per customer requirements
Output Power Ablation or resection: ≤351W
Coagulation or hemostasis: ≤111W
Working Frequency 100 KHz ± 10%
Dimension 405 × 440 × 130mm (L × W × H)
Working Mode Ablation and resection: level 1-10
Coagulation: level 1-10
Weight 7.0kg
Technical Principle
The plasma technology generates plasma energy by stimulating NaCl in physiological saline with a 100KHz square wave. High-speed charged particles in the plasma break molecular bonds of human tissue, causing proteins and other tissues to decompose and vaporize into low molecular weight gases including H₂, O₂, CO₂, N₂, and methane.
Under a stable 100KHz square wave electric field, particles achieve extended acceleration time, forming high-speed charged particles with kinetic energy sufficient to break molecular bonds while causing minimal damage to surrounding tissues. Cutting, ablation, and hemostasis procedures are completed within the 40-70℃ temperature range.
Plasma energy surgical system technical diagram
Technical System Diagram
Manufacturing Process
Factory manufacturing process step 1
Manufacturing Process Step 1
Factory manufacturing process step 2
Manufacturing Process Step 2
Exhibition Showcase
Medical exhibition display 1
Exhibition Display 1
Medical exhibition display 2
Exhibition Display 2
Medical exhibition display 3
Exhibition Display 3
Medical exhibition display 4
Exhibition Display 4
Medical exhibition display 5
Exhibition Display 5
Medical exhibition display 6
Exhibition Display 6