| Brand Name: | Better |
| Model Number: | UUS01 |
| MOQ: | 100 piece |
| Price: | Negotiable |
| Packaging Details: | paper carton |
| Payment Terms: | T/T,L/C |
This disposable intrauterine anti-adhesion stent is a sterile physical barrier solution made of medical-grade silicone, specifically developed to address the high recurrence rate of intrauterine adhesions (IUA).
Intrauterine adhesions primarily result from injury to the endometrial basal layer caused by curettage and other intrauterine interventions. Even following hysteroscopic adhesiolysis, fresh surgical wound surfaces within the uterus are prone to re-adhesion, leading to recurrent adhesion formation and poor reproductive outcomes.
• IUA incidence following repeated curettage: 25%-30%
• Adhesion recurrence rate after severe IUA surgery: up to 62.5%
• Pregnancy rate post severe IUA surgical repair: 22.5%-33.3%
Recommended as a Grade-B physical anti-adhesive option in the Chinese Expert Consensus on Intrauterine Adhesion, this silicone stent physically separates raw tissue surfaces. It is indicated not only for IUA postoperative care but also for other hysteroscopic procedures that generate substantial intrauterine wound areas.
Rounded soft edges follow natural uterine cavity contours, avoiding excessive compression on uterine side walls while preserving endometrial blood perfusion. A comprehensive size portfolio accommodates varied patient uterine cavity anatomy.
Built-in drainage channel enables unobstructed discharge of intrauterine exudate after operation. Constructed from soft silicone material, it minimizes mechanical irritation and discomfort to the cervical canal.
Supplied with a purpose-built inserter for straightforward clinical handling. Positioning holes support simple placement and retrieval under hysteroscopic vision. Moderate material flexibility facilitates smooth cervical passage. Surface raised protrusions deliver stable anchoring, effectively preventing shifting or accidental dislodgement.
Stent body: medical-grade silicone; matching inserter: medical-grade plastic. Factory pre-sterilized for single-use application. Eliminates cross-contamination risk and reduces hospital workload for re-processing and sterilization.
| Model | AZ32/34 | AZ30/32 | AZ28/31 | AZ26/30 | AZ24/30 | AZ22/26 | AZ20/25 | AZ18/24 | AZ16/23 | AZ14/20 |
|---|---|---|---|---|---|---|---|---|---|---|
| Stent Width (mm) | 32 | 30 | 28 | 26 | 24 | 22 | 20 | 18 | 16 | 14 |
| Stent Length (mm) | 34 | 32 | 31 | 30 | 30 | 26 | 25 | 24 | 23 | 20 |
|
|
| Brand Name: | Better |
| Model Number: | UUS01 |
| MOQ: | 100 piece |
| Price: | Negotiable |
| Packaging Details: | paper carton |
| Payment Terms: | T/T,L/C |
This disposable intrauterine anti-adhesion stent is a sterile physical barrier solution made of medical-grade silicone, specifically developed to address the high recurrence rate of intrauterine adhesions (IUA).
Intrauterine adhesions primarily result from injury to the endometrial basal layer caused by curettage and other intrauterine interventions. Even following hysteroscopic adhesiolysis, fresh surgical wound surfaces within the uterus are prone to re-adhesion, leading to recurrent adhesion formation and poor reproductive outcomes.
• IUA incidence following repeated curettage: 25%-30%
• Adhesion recurrence rate after severe IUA surgery: up to 62.5%
• Pregnancy rate post severe IUA surgical repair: 22.5%-33.3%
Recommended as a Grade-B physical anti-adhesive option in the Chinese Expert Consensus on Intrauterine Adhesion, this silicone stent physically separates raw tissue surfaces. It is indicated not only for IUA postoperative care but also for other hysteroscopic procedures that generate substantial intrauterine wound areas.
Rounded soft edges follow natural uterine cavity contours, avoiding excessive compression on uterine side walls while preserving endometrial blood perfusion. A comprehensive size portfolio accommodates varied patient uterine cavity anatomy.
Built-in drainage channel enables unobstructed discharge of intrauterine exudate after operation. Constructed from soft silicone material, it minimizes mechanical irritation and discomfort to the cervical canal.
Supplied with a purpose-built inserter for straightforward clinical handling. Positioning holes support simple placement and retrieval under hysteroscopic vision. Moderate material flexibility facilitates smooth cervical passage. Surface raised protrusions deliver stable anchoring, effectively preventing shifting or accidental dislodgement.
Stent body: medical-grade silicone; matching inserter: medical-grade plastic. Factory pre-sterilized for single-use application. Eliminates cross-contamination risk and reduces hospital workload for re-processing and sterilization.
| Model | AZ32/34 | AZ30/32 | AZ28/31 | AZ26/30 | AZ24/30 | AZ22/26 | AZ20/25 | AZ18/24 | AZ16/23 | AZ14/20 |
|---|---|---|---|---|---|---|---|---|---|---|
| Stent Width (mm) | 32 | 30 | 28 | 26 | 24 | 22 | 20 | 18 | 16 | 14 |
| Stent Length (mm) | 34 | 32 | 31 | 30 | 30 | 26 | 25 | 24 | 23 | 20 |