logo
Good price  online

products details

Home > Products >
ENT Probe
>
Ultrafine Ultra-long ENT Plasma Electrode for Laryngeal Augmentation & Papilloma Removal

Ultrafine Ultra-long ENT Plasma Electrode for Laryngeal Augmentation & Papilloma Removal

Brand Name: Better/Vanway
Model Number: VF08E
MOQ: 1 unit
Price: Negotiable
Packaging Details: paper carton
Payment Terms: T/T,L/C,Western Union
Detail Information
Place of Origin:
CHINA
Certification:
ISO, CE
Stone Capacity:
Effective For Calculi ≤3cm
Surgical Approach:
Transforaminal Endoscope Framework
Power:
10W-300W Stepwise Adjustable
Use:
Electric
Input Volts:
198-240V 50Hz, 100-120V 60Hz
Valid Time:
3 Years
Power Output Settings:
Default Level
Required Environment:
Saline Environment
Safety Features:
Automatic Shutdown, Overload Protection
Powersupply:
AC 110-240V, 50/60Hz
Probe Identification:
Automatic
Applying Field:
ENT Treatment
Temperature Display:
Yes
Wavelength:
532nm±5%
Supply Ability:
1000000 set per year
Highlight:
Rf Ablation System, Rf Ablation Devices
Product Description
Product Overview

The VF08E Bipolar RF Plasma Electrode is a specialized single-use ENT surgical electrode designed for deep laryngeal minimally invasive procedures. Built with an ultrafine and ultra-long shaft, it easily reaches deep surgical sites while preventing probe blockage during operation.

Powered by low-temperature plasma technology, it delivers precise ablation and tissue management with minimal thermal injury to surrounding healthy tissues. This electrode enables clear surgical visualization and reliable clinical outcomes for delicate laryngeal surgeries.

Key Characteristics
  • Ultrafine and ultra-long shaft design, ideal for accessing deep laryngeal surgical areas
  • Anti-blockage structure to prevent probe clogging during surgery
  • Bipolar low-temperature plasma technology, minimizing thermal damage to adjacent tissue
  • Precise ablation and cutting for delicate laryngeal tissue
  • Single-use disposable electrode, convenient and safe for clinical application
Advanced Technology

The probe utilizes radio frequency plasma technology. High-frequency energy ionizes conductive saline to generate plasma at the electrode tip. This plasma breaks molecular bonds within soft tissue, enabling controlled ablation at relatively low temperatures.

Working Principle

During ENT surgery, the probe is positioned at the target tissue. When RF energy is activated, a plasma field forms at the electrode tip, processing thyroidectomy with cutting, hemostasis, and ablation functions.

Clinical Applications
  • Laryngeal augmentation
  • Laryngeal papilloma removal
  • Other minimally invasive laryngeal surgical procedures
Technical Parameters
Product Type Disposable RF Plasma Probe Electrode
Application Laryngeal augmentation, laryngeal papilloma removal, other minimally invasive laryngeal surgical procedures
Surgical Field ENT Surgery
Technology RF Plasma
Function Ablation, Cutting, Hemostasis
Use Single Use
Sterilization Sterile Packaging
Working Mode Plasma
Customization Services

OEM and ODM services are available. Customization options include Surgery ENT Probe, Plasma Spine Probe, Spine Surgery Probe, length, shaft diameter, tip configuration, cable length, and connector compatibility. Technical support, after-sales service, and product training are provided.

Shipping Information
  • Carrier: Selected shipping provider
  • Delivery time: 7–12 business days
  • Shipping cost calculated at checkout
  • International shipping available
Frequently Asked Questions
What procedures is this probe designed for?

It is designed for laryngeal augmentation, laryngeal papilloma removal, and other minimally invasive procedures.

What functions does it provide?

It supports tissue ablation, cutting, and hemostasis.

Is it disposable?

Yes, it is sterile and intended for single use.

Can the probe be customized?

Yes, customization is available.

Product Images
Good price  online

Products Details

Home > Products >
ENT Probe
>
Ultrafine Ultra-long ENT Plasma Electrode for Laryngeal Augmentation & Papilloma Removal

Ultrafine Ultra-long ENT Plasma Electrode for Laryngeal Augmentation & Papilloma Removal

Brand Name: Better/Vanway
Model Number: VF08E
MOQ: 1 unit
Price: Negotiable
Packaging Details: paper carton
Payment Terms: T/T,L/C,Western Union
Detail Information
Place of Origin:
CHINA
Brand Name:
Better/Vanway
Certification:
ISO, CE
Model Number:
VF08E
Stone Capacity:
Effective For Calculi ≤3cm
Surgical Approach:
Transforaminal Endoscope Framework
Power:
10W-300W Stepwise Adjustable
Use:
Electric
Input Volts:
198-240V 50Hz, 100-120V 60Hz
Valid Time:
3 Years
Power Output Settings:
Default Level
Required Environment:
Saline Environment
Safety Features:
Automatic Shutdown, Overload Protection
Powersupply:
AC 110-240V, 50/60Hz
Probe Identification:
Automatic
Applying Field:
ENT Treatment
Temperature Display:
Yes
Wavelength:
532nm±5%
Minimum Order Quantity:
1 unit
Price:
Negotiable
Packaging Details:
paper carton
Delivery Time:
Negotiable
Payment Terms:
T/T,L/C,Western Union
Supply Ability:
1000000 set per year
Highlight:
Rf Ablation System, Rf Ablation Devices
Product Description
Product Overview

The VF08E Bipolar RF Plasma Electrode is a specialized single-use ENT surgical electrode designed for deep laryngeal minimally invasive procedures. Built with an ultrafine and ultra-long shaft, it easily reaches deep surgical sites while preventing probe blockage during operation.

Powered by low-temperature plasma technology, it delivers precise ablation and tissue management with minimal thermal injury to surrounding healthy tissues. This electrode enables clear surgical visualization and reliable clinical outcomes for delicate laryngeal surgeries.

Key Characteristics
  • Ultrafine and ultra-long shaft design, ideal for accessing deep laryngeal surgical areas
  • Anti-blockage structure to prevent probe clogging during surgery
  • Bipolar low-temperature plasma technology, minimizing thermal damage to adjacent tissue
  • Precise ablation and cutting for delicate laryngeal tissue
  • Single-use disposable electrode, convenient and safe for clinical application
Advanced Technology

The probe utilizes radio frequency plasma technology. High-frequency energy ionizes conductive saline to generate plasma at the electrode tip. This plasma breaks molecular bonds within soft tissue, enabling controlled ablation at relatively low temperatures.

Working Principle

During ENT surgery, the probe is positioned at the target tissue. When RF energy is activated, a plasma field forms at the electrode tip, processing thyroidectomy with cutting, hemostasis, and ablation functions.

Clinical Applications
  • Laryngeal augmentation
  • Laryngeal papilloma removal
  • Other minimally invasive laryngeal surgical procedures
Technical Parameters
Product Type Disposable RF Plasma Probe Electrode
Application Laryngeal augmentation, laryngeal papilloma removal, other minimally invasive laryngeal surgical procedures
Surgical Field ENT Surgery
Technology RF Plasma
Function Ablation, Cutting, Hemostasis
Use Single Use
Sterilization Sterile Packaging
Working Mode Plasma
Customization Services

OEM and ODM services are available. Customization options include Surgery ENT Probe, Plasma Spine Probe, Spine Surgery Probe, length, shaft diameter, tip configuration, cable length, and connector compatibility. Technical support, after-sales service, and product training are provided.

Shipping Information
  • Carrier: Selected shipping provider
  • Delivery time: 7–12 business days
  • Shipping cost calculated at checkout
  • International shipping available
Frequently Asked Questions
What procedures is this probe designed for?

It is designed for laryngeal augmentation, laryngeal papilloma removal, and other minimally invasive procedures.

What functions does it provide?

It supports tissue ablation, cutting, and hemostasis.

Is it disposable?

Yes, it is sterile and intended for single use.

Can the probe be customized?

Yes, customization is available.

Product Images